What Proxmox VE SDN does for multi-tenant clusters and when you need it
Proxmox VE SDN defines zones, VNets and subnets centrally, so guests receive isolated networks without someone editing bridges and VLAN settings on every node. That matters when several teams, customers or environments share one cluster and each needs its own separated network. Proxmox VE integrates the KVM hypervisor and Linux Containers with software-defined storage and networking on one platform, so virtual machines and containers draw on the same network objects. The cluster is multi-master, and the Proxmox Cluster File System replicates configuration to all nodes in real time, which is what allows one SDN definition to apply across the cluster. Confirm in the current admin guide exactly how definitions are applied and when they become active on each node.
Plain Linux bridges and per-node VLANs remain a sound choice for a small cluster with one administrative team, a handful of networks and infrequent changes. The cost shows up as the cluster grows. Each new tenant network needs matching bridge and VLAN configuration on every node that might run its guests, and a mismatch can leave a guest without connectivity after a migration or after high availability restarts it on another host. Before choosing, count your tenants and networks, your node count, how often networks change and who is allowed to change them. If those numbers keep rising, the central model is worth evaluating against your current process.
The zone type determines what the network underneath must provide, so choose it with your network team. The topic covers Simple, VLAN, QinQ, VXLAN and EVPN zones, and each depends on different capabilities in your switches, VLAN trunks, addressing and routing. Ask your network team whether they can carry tagged traffic to every node, whether tenant networks must span nodes or sites, and whether routing between tenants must be controlled at the fabric. Confirm each zone's prerequisites in the current admin guide. Also check the status of IPAM and DHCP, which are technology previews, before you build a process that depends on them.
Network isolation is only one part of a multi-tenant design. SDN separates the paths between guests, but who may create or change those objects is decided by the cluster's user realms and roles. Proxmox VE supports Linux PAM, its built-in authentication server, LDAP, Active Directory and OpenID Connect realms, along with second factors such as TOTP and WebAuthn, so you can scope administrative access to match tenant ownership. Plan that access model alongside the network design. Before you commit, test in a non-production cluster that a guest in one zone cannot reach a guest in another, and record who approves SDN changes.
Which Proxmox VE SDN zone type fits which network design
This table compares the five Proxmox VE SDN zone types on where isolation sits, what physical network each needs, whether traffic crosses nodes through an overlay, and what skills operation requires. Read the physical network column first, because VLAN, QinQ, VXLAN and EVPN depend on configuration outside Proxmox VE in different ways. Limits on VNet counts and tag ranges are not listed here, so confirm them in the SDN documentation for your running version before settling the design.
| Zone type | Isolation boundary | Physical network and external configuration | Overlay and operating skills |
|---|---|---|---|
| Simple | Each VNet is a local bridge on each node, with no tagging applied | Existing node bridge uplink only; no switch changes required | No overlay and no cross-node transport from SDN; minimal skills, suited to single-node or lab designs |
| VLAN | 802.1Q tag per VNet, isolating traffic at Layer 2 across the trunk | Switch ports must trunk the tagged VLANs to every node; depends on switch configuration outside Proxmox VE | No overlay; needs switch VLAN administration and Linux bridge tagging knowledge |
| QinQ | Stacked outer service tag and inner VLAN tag separate tenants | Switches must support stacked (double) tagging; configured outside Proxmox VE | No overlay; adds provider-side tag design and MTU planning, with tag range limits to confirm in the docs |
| VXLAN | VXLAN network identifier per VNet, carried in UDP between nodes | Routed IP reachability between node addresses; underlay MTU must allow encapsulation overhead | Spans nodes; needs IP underlay design, peer maintenance and overlay troubleshooting skills |
| EVPN | VXLAN segments advertised through BGP EVPN routes | BGP peering with the fabric or route reflectors; depends on FRR or fabric configuration outside Proxmox VE | Spans nodes with a BGP control plane; requires BGP and EVPN operations skills, the highest of the five |
Choosing a zone type for tenant isolation in Proxmox VE SDN
Start the decision with the physical network you already run, because that determines which zone types are cheap to operate. Ask whether you control the switch ports that carry traffic from each Proxmox VE node, and whether you can trunk tagged VLANs to every host through your normal change process. If you do, a VLAN zone is usually the simplest fit for tenant separation, since each tenant maps to a tagged network that your switches already understand. If tenants must carry their own tags inside a provider tag, evaluate QinQ, but confirm with your switch vendor that the hardware, MTU and tag handling support double tagging before you commit to it.
Next, count the tenants and write down the isolation promise you make to each of them. With VLAN-based zones, every tenant consumes identifiers on every trunk, so the tenant count sets the size of the design and the usable ID range must be confirmed in your switch configuration and in the SDN documentation for your Proxmox VE version. Then state precisely what the promise covers. Separate broadcast domains may be enough for internal teams, while tenants who must never reach each other, even through shared gateways, need additional controls. Those controls, including the distributed firewall, are covered in a sibling section and should be scoped now, not after tenants are live.
Choose VXLAN when the underlay is hard to change. If the switches belong to a network team with long change cycles, or the nodes sit across routed segments where trunking every VLAN is impractical, VXLAN carries tenant Ethernet inside UDP over the IP network you already have. The underlay then needs IP reachability between nodes and enough MTU for encapsulation overhead. The cost is a larger troubleshooting surface and an MTU plan that must hold on every path, so test the path MTU between all nodes before you create the zone.
EVPN is worth its added control-plane complexity when you need dynamic MAC and IP advertisement across many nodes, or when the tenant networks must integrate with a routed fabric that already speaks BGP. For a small cluster with few tenants, plain VXLAN is often easier to run and to debug. If you adopt EVPN, confirm that your team can operate BGP sessions and route policy. Treat IPAM and DHCP integrations as technology previews for this purpose: do not make them the only mechanism that keeps tenant addressing correct without a tested fallback.
Decide the zone type before creating any guests, because it constrains VNet and subnet design. A VNet belongs to a zone, so changing the zone later usually means rebuilding networks, re-attaching guest NICs and re-addressing workloads. Record the decision in a short design note: zone type, VLAN or VNI ranges per tenant, MTU, subnet plan, where gateways live, and who owns the switch configuration. Validate that record on a non-production cluster first. The no-subscription repository is described for testing and non-production use, so it suits that validation, while production clusters should use the enterprise repository with a valid subscription.
How to build a Proxmox VE SDN configuration step by step
This sequence takes a Proxmox VE cluster from switch and host prerequisites to isolated VNets that guests can use, with a check at each stage. The steps follow the same order whichever zone type you choose, but the prerequisites and verification details change with the zone. Confirm each menu path and command against the Proxmox VE administration guide for your installed version before you run it.
Confirm physical and switch prerequisites for the zone
Before you touch SDN, settle on the zone type and check what it requires underneath. A VLAN zone needs each node's uplink to carry the chosen VLAN IDs as tagged traffic, so the switch ports facing the nodes must be trunks that allow those IDs. VXLAN and EVPN zones need IP reachability between node addresses on the underlay network, and the MTU must leave room for encapsulation overhead, so confirm the MTU end to end. EVPN also needs a routing design agreed with your network team. Done means every node can reach its peers on the underlay and the uplinks carry the required VLAN IDs.
Create the zone on every node that needs it
In the web interface, open Datacenter, then SDN, and create a zone of the type you chose. For a VLAN zone, name the bridge or physical interface it uses. For VXLAN or EVPN, enter the peer or controller parameters the administration guide lists for that zone type. Zone changes stay pending until you apply them in step 5, so the running network does not change yet. Verify by confirming the zone appears on every node that will carry guests, and check the bridge or overlay interface on each node with a command such as ip -br link.
Create VNets for each isolated segment
Create one VNet for each segment the design needs, such as a tenant, an application tier or an environment. Use names that match your IP plan so that later troubleshooting is easy. In a VLAN zone, each VNet carries a VLAN tag, and in a VXLAN or EVPN zone it carries a VXLAN network identifier. Confirm the tags or identifiers do not collide with existing switch VLANs or other overlays. Verify that each VNet appears in the SDN section of the web interface and that the same list is visible from the CLI, using the SDN commands the administration guide documents for your version.
Add subnets and gateways to each VNet
Attach a subnet in CIDR notation to each VNet and set the gateway address that guests will use as their default route. Decide early who answers for the gateway, whether a router, a firewall or a host, and whether DHCP and IP address management come from Proxmox VE. Both of those are technology previews in this area, so confirm their status for your version and treat them as something to test before production use. Verify that each subnet appears under its VNet and that the gateway address matches your IP plan with no overlaps between subnets.
Apply the SDN configuration across the cluster
Apply the pending SDN changes from the SDN section of the web interface, or run the equivalent apply step from the CLI as the administration guide describes for your version. The Proxmox Cluster File System replicates the configuration to every node, and each node then builds its local network setup. Verify that no pending or error state remains, that every node reports the zone and VNets, and that the expected bridges or overlay interfaces are up on each node with ip -br addr. Do not continue until every node shows the same result.
Attach guest NICs to the correct VNet
For each KVM guest, open its hardware settings in the web interface and set the network device's bridge to the VNet name. For each LXC container, set the network interface's bridge to the same VNet. Inside each guest, assign an address from that VNet's subnet and set the gateway. Verify by confirming the guest's interface shows the expected VNet and that the guest has an address in the right subnet. Keep a record of which guest sits on which VNet so that the isolation tests in the next step have a clear expected result.
Test gateway reach and VNet isolation
From a test guest in each VNet, confirm it reaches its gateway. Then confirm that a guest in one VNet cannot reach a guest in another VNet unless an explicit rule allows it. If a router or firewall connects the VNets, it will route traffic unless you filter it, so the isolation depends on that device's policy as well as on SDN. Migrate one test guest to another node and repeat the checks, since guests must keep their VNet membership after they move. Record the results with the commands and outputs you used, and treat any unexpected path as a failed step to fix before go-live.
How SDN changes are applied and verified across cluster nodes
An SDN change in Proxmox VE is a cluster-level operation with per-node effects. Proxmox VE clusters use a multi-master design in which every node can perform all management tasks, and the Proxmox Cluster File System replicates configuration to all nodes in real time. The zones, VNets and subnets you define are therefore shared by the whole cluster. The network devices those definitions need, such as VLAN-aware bridges, VLAN subinterfaces or VXLAN tunnel endpoints, are still built on each host. A successful save on one node shows that the configuration replicated, but it does not show that every host applied it. Plan the change around that gap and treat the cluster-wide save as the first step of verification.
A practical routine starts with the apply itself. Confirm that the change finished without errors on each node, including the node where you made the edit. Then check each node's network state directly. On every host, confirm that the bridges, VLAN tags or VXLAN devices for the affected zone exist and match the intended configuration, and compare the output across nodes. Exact commands and apply behavior depend on your installed version, so confirm them in the administration guide for that release before you write the runbook. Next, test guest connectivity from more than one node. Place test guests on the VNet on different hosts and check gateway reachability, traffic between them and paths that leave the VNet. A path may work from one host and fail from another, especially where traffic crosses tunnels between nodes.
Record every change in change control before you close it. Capture the configuration diff, the time of the apply, the nodes checked, the method used for each check, the connectivity test results and the name of the person who approved the change. Note which nodes were healthy before the change, because a change made while a host is already out of sync is hard to diagnose later. Record the rollback path as well: which configuration to restore, in what order, and how you will confirm each node returned to its prior state. Keep this record with your cluster documentation so the next engineer can see what the network looked like before and after the change.
This is where verification connects to high availability. When a node fails, HA recovery restarts its guests on surviving nodes, and those guests keep working network access only if the target node has applied the SDN configuration correctly. A node with a stale or failed network apply can restart a guest that boots but cannot reach its network, which can look like a successful recovery in the HA view. Proxmox VE HA needs at least three cluster nodes for reliable quorum, shared storage for guests and watchdog-based fencing so a failed node is reset before its guests are recovered elsewhere. After each SDN change that touches a VNet used by HA-managed guests, run a planned failover test in a maintenance window and confirm that the guest starts on another node with working connectivity. Decide in advance who owns that test and what blocks the next change if it fails.
Tenant isolation risks in Proxmox VE SDN and how to reduce them
Tenant isolation in Proxmox VE SDN comes from several controls working together: the zone type and its physical boundary, firewall policy on each guest and host, a dedicated management network, and disciplined access to configuration. The cards below cover what each control protects and what to check before tenants share a cluster. Confirm firewall and permission details on the related pages and in the documentation for the version you deploy.
Zone type sets the isolation boundary
Each SDN zone type carries tenant traffic differently: Simple, VLAN, QinQ, VXLAN and EVPN zones separate networks at different layers, so the strength of isolation depends on whether the boundary is a switch port, a VLAN tag or an overlay identifier. For an illustrative design, two tenants on VLAN zones share the same physical uplinks, which makes trunk allowed VLAN lists part of the security review. Before go-live, confirm with your network team which trunks carry each zone and how overlay traffic is routed between nodes.
SDN is not a firewall
Separating VNets and subnets controls which networks exist and how they connect, but it does not decide which ports or sources a guest may reach. Host and guest firewall rules must be designed separately, using the Proxmox VE firewall and its rule levels, which are covered on the distributed firewall page. Check that every tenant subnet has an explicit policy before workloads are placed on it, and confirm the default policy in your version before relying on it.
Management traffic on its own network
Cluster communication, the web interface, live migration and storage traffic all reach the same nodes, so a tenant network that shares those paths weakens every boundary above it. Place management and cluster traffic on a dedicated network that tenant VNets cannot route to, and restrict who can reach it. Verify this with a reachability test from a tenant guest, because an SDN configuration can look correct in the interface while a host still has a route into that network.
Role-based permissions and authentication realms
SDN configuration is changed through the same permission model as the rest of the cluster. Proxmox VE grants access through roles assigned to users, groups or API tokens on specific paths, and users can come from Linux PAM, the Proxmox VE authentication server, LDAP, Active Directory or OpenID Connect realms. Map each team to the narrowest role that covers its networks, and review which realm each administrator signs in through. Confirm the exact privileges that cover SDN paths in the user management documentation for your version.
Second factors for SDN administrators
Anyone who can edit zones, VNets or subnets can change which tenant reaches which network, so their sign-in should require more than a password. Proxmox VE supports TOTP, WebAuthn, YubiKey OTP and recovery keys as second factors. Decide which accounts must enrol a factor, how recovery keys are stored and who can reset a lost factor. Test the enrolment and recovery path before it is needed, and confirm which factor types each realm supports in your version.
Log and review every SDN change
Network changes made under time pressure can expose one tenant to another, so each change to zones, VNets, subnets and related firewall settings needs a record. Keep the change request, the person who applied it and the post-change verification together. Proxmox VE replicates cluster configuration to all nodes, so check the resulting configuration on more than one node to confirm the same state everywhere. Schedule periodic reviews of the live SDN configuration against the approved design.
Where IPAM and DHCP fit in your Proxmox VE SDN addressing plan
Defining a subnet in Proxmox VE SDN tells the cluster which addresses exist. It does not settle who hands those addresses out, which system records them, or what happens when two tenants want the same range. Before you create VNets and subnets for your zones, make three decisions in writing: who assigns guest addresses, whether an external DHCP or IPAM system is the source of truth, and how overlapping address space will be handled across tenants. These choices affect the zone design, so they belong in the initial plan and should be settled before the first guest is attached. A VNet that isolates traffic at Layer 2 does not, by itself, make identical subnets safe to route or to resolve by name.
Start with address assignment. Guests can be configured statically by their owners, receive leases from a DHCP server outside the cluster, or use DHCP and IPAM components built into Proxmox VE SDN. Each option determines where lease records live and which service answers when a guest asks for an address. If an external system is the source of truth, the SDN subnet should not act as a second writer for the same ranges, or you will get conflicting records. Ask your network team who owns reservations, DNS registration and cleanup when a guest is retired. Also confirm that DHCP requests reach the guest after a live migration or an HA restart on any node that may host it, because a relay or broadcast domain that works on one node may not work on another.
Overlapping address space is the decision teams most often postpone. If two tenants both use the same private range, the cluster can keep their VNets separate at the bridge level, but the overlap becomes a problem as soon as a shared firewall, load balancer, monitoring host or DNS resolver sits in the path. Decide whether tenants receive unique ranges from a central allocation, whether NAT is applied at the edge, or whether each tenant gets a separate routing domain, and who approves exceptions. Confirm with your network design how the VXLAN or EVPN zone you select carries routes for overlapping prefixes. The answer depends on routing outside the cluster as much as on the subnet object inside it.
Some IPAM and DHCP components in Proxmox VE SDN may still be technology previews. Preview features can change between releases and may not cover every option you would use in production. Before you rely on them, confirm the current preview status, the supported features and any known limitations in the exact release you plan to run, and check those notes again before each upgrade. You have two sound paths: run the built-in components in production with a tested rollback plan, or keep an external system as the system of record and use the built-in components only where their support statement covers your use. Document which path you chose and the reason for it, so the decision can be reviewed when the release changes.
Turn these choices into a short addressing record before the first zone is created. Include the owner of each subnet, the system that issues each lease, the reservation process, the overlap policy and the steps for retiring addresses. Then test the design against real failure paths. Run a guest that renews its lease, migrate it to another node, restart it under HA and confirm that it keeps the expected address and name. Test what happens when the external IPAM or DHCP service is unreachable. If you bring in an implementation partner, ask for these tests to be listed as separate items in the written scope so the cost and effort of validation are visible before work starts.
Proxmox VE SDN limits and technology previews to confirm before you build
Each card names one item to verify before you commit to a zone design. Confirm the answer in the official admin guide, the release notes for the version you run, or a lab test on your own hardware, and record the result in your design document.
Technology preview status
Some SDN components, including IPAM and DHCP, may still be labeled technology previews. Preview status depends on the exact Proxmox VE version you run, so check the label for each component in the release notes for that version. If a component is a preview, decide whether your design can work without it, and note the decision so a later upgrade does not change the plan silently.
External switch and router configuration
VLAN, VXLAN and EVPN zones depend on the physical network. The upstream switch, router or fabric must carry the tags, overlay traffic or EVPN routing that your SDN definitions expect. For each zone type, confirm the required external settings in the official admin guide, assign an owner for that configuration, and prove the path with a single test VNet on your hardware before you roll it out.
HA and live migration behavior
Proxmox VE HA needs at least three cluster nodes, shared storage for guests, redundant hardware and watchdog-based fencing. Confirm in the HA wiki and the admin guide that a guest attached to your chosen zone can restart on another node with the same network definitions present. Then test live migration and an HA failover on your hardware and confirm that the guest keeps its network connectivity afterward.
Storage and backup compatibility
Proxmox VE supports local storage on LVM, directories and ZFS, and network storage on iSCSI, NFS, CIFS, Ceph RBD, CephFS and Proxmox Backup Server. The SDN zone does not change which storage you use, but backup and storage traffic may cross the same VLAN or VXLAN overlay. Check the routing, MTU and firewall path between your nodes and the backup target in a lab test before you rely on that path for restores.
Support tier for SDN questions
Proxmox VE subscriptions are priced per CPU socket per year, and the pricing page lists Community with no support tickets, Basic with 3 tickets and 1 business day response, Standard with 10 tickets and 4-hour response, and Premium with unlimited tickets and 2-hour response. All tiers include the same software features. Ask Proxmox in writing whether SDN questions fall under the tier you buy, because that coverage is set by the subscription terms.
Version lifecycle and upgrade path
Proxmox VE 9.0 was released on August 5, 2025 on Debian 13, 9.1 on November 19, 2025, and 9.2 with a dynamic load balancer on May 21, 2026. Each version is supported at least as long as its matching Debian release has security support, roughly 3 years. Before you build, confirm in the release notes which SDN behavior changes between your starting version and the version you plan to run next year.
Questions buyers ask about Proxmox VE SDN design and implementation
Do we need software-defined networking at all for our Proxmox VE cluster?
Not always. If each tenant or application group can sit on one existing VLAN with static addressing, VLAN-tagged bridges configured on each node may be enough, and that design is easier to troubleshoot. SDN becomes worth considering when you need many isolated networks that appear identically on every node, when tenants need their own address ranges, or when you want network definitions managed centrally instead of edited host by host. Ask how many networks you expect to create over the next few years, who will create them, and whether your switch fabric can carry VLANs or overlays across every node. Confirm the answer in a lab before committing, because the zone type you choose sets the physical and switch requirements.
What drives the cost and effort of a Proxmox VE SDN build?
The main drivers are the number of zones and tenants, the state of the physical and switch fabric, whether you need IPAM or DHCP integration, how the design is tested against high availability and backups, and how much documentation your team needs at handover. Each zone adds configuration on every node and sometimes on the switches, so a few zones on a clean, documented fabric is far smaller work than many tenants on a fabric nobody has reviewed. An external IPAM or DHCP service adds dependencies and test cases. Ask for a quote that separates one-time design and build work from any recurring support, and ask what a later change, such as adding a tenant, will involve.
Can our own team build a Proxmox VE SDN design without outside help?
Often yes, if your engineers already run Linux bridges, VLAN trunks and routing, and you have a lab cluster where they can test changes safely. The difficult part is usually the switch side: trunk allowances, MTU on overlay paths, and how routing or EVPN peering is set up with your network team, not the Proxmox VE settings themselves. Internal teams tend to struggle most with three things: testing failure cases such as a node reboot during a migration, keeping the design documented, and owning changes after handover. Decide which of these your team can cover, then bring in a partner for the gaps. The software is licensed under AGPLv3 and can be used without a subscription, so the open question is capacity and skills.
What do we need to provide for an SDN implementation project?
Most of the project depends on access and information from your side. Plan to provide:
- Switch access: credentials or approved change requests for VLAN, trunk and routing changes on the switches involved.
- An addressing plan: VLAN IDs, subnets, gateways, DNS servers and any IP ranges reserved for tenants.
- A lab cluster: a non-production environment where designs can be validated before cutover.
- Change windows: agreed times for network changes, cutover and rollback.
- Named owners: someone from networking, virtualization and security who can make decisions quickly.
- Current documentation: diagrams and inventories of the fabric, existing bridges and firewall rules.
If any item is missing, the schedule and the quote usually change, so raise gaps early.
How long does a Proxmox VE SDN project take?
Duration depends on scope rather than on a standard figure. The main factors are the number of zones and tenants, the number of nodes, whether switch changes need vendor input or a change board decision, and how many test cycles the design requires. A single zone on a clean fabric with a lab available is a much smaller project than a multi-tenant EVPN design across several racks with IPAM integration. Most engagements are fixed-scope, so the timeline is written into the agreed scope before work starts. Ask for milestones such as design sign-off, lab validation, change windows, cutover and handover, and ask how your change control process and staff availability affect the calendar.
How is the price of a Proxmox VE SDN implementation set?
DeployOpen does not publish a price list. A quote follows from the written scope, which should list zones, tenants, nodes, switch changes, IPAM or DHCP integration, testing and documentation. Implementation fees are separate from Proxmox VE subscription costs. The vendor prices subscriptions per CPU socket per year: according to the Proxmox VE pricing page, Community is 120 euros with no support tickets, Basic is 370 euros, Standard is 550 euros and Premium is 1,100 euros. All tiers include the same software features and differ in support entitlements and enterprise repository access. Confirm current vendor prices directly, since they can change, and ask any partner to show one-time work and recurring support as separate lines.
Which Proxmox VE SDN features are still technology previews?
IPAM and DHCP integration are the components to check first, because they are flagged as technology previews. Treat them as features to validate in a lab before your design depends on them. Preview status can change between releases, so check the Proxmox VE documentation for the exact version you run before deciding. Plan a fallback, such as an external IPAM or DHCP service you already operate, and ask any partner how they would handle a preview feature that changes during a major upgrade. Record the decision in the design document so the next team knows why the choice was made.
What should we test before putting Proxmox VE SDN into production?
Test the failure cases you will actually face, not only the happy path. Check that guests keep their network after a node failure and HA recovery, that live migration works between nodes using the same zones, and that backups and restores of guests on VNets succeed. Test a switch failover and confirm that tenants stay isolated. Remember the cluster prerequisites: HA needs at least three nodes for reliable quorum, shared storage for guests, redundant hardware and watchdog-based fencing, so a lab that lacks these will not prove the design. Keep test results, rollback steps and the change record together so the handover is verifiable.
Which Proxmox VE documentation to check before you commit to a design
Before you choose between Simple, VLAN, QinQ, VXLAN and EVPN zones, check what the vendor documents as supported for the exact Proxmox VE release you plan to run. Start with the Proxmox VE product overview, which describes the platform and what it integrates, including software-defined networking. Then read the introduction chapter of the Proxmox VE administration guide, which explains the cluster, storage and networking model that SDN builds on. Both come from Proxmox Server Solutions, and together they give you the baseline for what the platform is meant to do in production.
Next, locate the SDN chapter in the administration guide for your target version and read the release notes for that same release. Proxmox VE 9.0 shipped on Debian 13 on August 5, 2025, 9.1 followed on November 19, 2025, and 9.2 was released on May 21, 2026. Those dates tell you when each release arrived, but the release notes tell you what changed in SDN, such as zone types, VNet handling, subnet options or controller settings. Record the version, the Debian base it sits on, and any SDN change that affects the zones you are considering. If you plan to use a release not listed here, confirm the same points in its notes.
Then check the preview status of each component in the design. The topic scope identifies IPAM and DHCP as technology previews, so confirm that status in the SDN chapter for your version rather than relying on this summary. Apply the same check to every zone type, controller and integration you intend to use. For each component, record whether it is documented as supported, marked as a preview, or not covered, along with the section you read. If a component is a preview, decide whether the design still works without it, and accept in writing that its behavior may change before it is stable.
Write the answers into the design document. Include the Proxmox VE version, the date you checked, the preview status for each component, and the documentation sections you relied on. This page summarizes design choices and does not replace the vendor documentation. If this page and the documentation for your version disagree, the documentation governs, and the design should be updated to match. Repeat the same checks before any upgrade, because supported behavior and preview status can change between releases, and a design approved on one version needs a fresh review on the next.
How DeployOpen scopes, builds and supports Proxmox VE SDN
DeployOpen plans, implements, hardens, documents and supports self-hosted platforms inside your own infrastructure, and Proxmox VE software-defined networking is delivered on the same basis. We start from a written, fixed scope that names the zone types, VNets, subnets and tenant boundaries in play. The build is tested, documented and handed to your team, and ongoing support is available as a retainer.
How we scope
- The written scope lists which zone types are in use: Simple, VLAN, QinQ, VXLAN or EVPN, and why.
- It maps VNets and subnets to each tenant, workload group or security zone that must stay isolated.
- Engagements are fixed-scope, with deliverables and timelines agreed in writing before work starts.
How we build
- Cluster nodes get consistent NIC, bridge and VLAN-aware configuration, checked against the chosen zone type.
- Isolation is verified from inside guests, covering VNet separation, gateway reachability and behavior when a node drops out.
- Technology preview components, such as IPAM or DHCP where applicable, are flagged and confirmed against your target release.
How we hand over
- Handover includes documentation of zones, VNets, subnets, bridges and the addressing plan as built.
- Runbooks cover adding a VNet, changing a zone and recovering a node's network configuration.
- Your team receives a test record showing which isolation checks passed, with dates and versions recorded.
How we support
- Retainers cover upgrades to newer Proxmox VE releases, with SDN changes reviewed against release notes.
- Changes to zone types or VNets go through the same test set before they reach production.
- Confirm with your team who owns the switch fabric, since VLAN trunks and EVPN peering span both sides.

