What SC-49 hardware-enforced separation requires and why it is rarely selected
If your organization needs stronger isolation between security domains than software controls can give, SC-49 is the control that asks for it, but it is not part of any SP 800-53B baseline. SC-49 requires hardware-enforced separation and policy enforcement mechanisms between defined security domains. In plain terms, the boundary between a high-value domain and the rest of the environment must be enforced by hardware, so that a compromised operating system, hypervisor or application on one side cannot override the policy that protects the other. SC-49 applies only when your organization selects it through tailoring or an overlay. Appendix C of SP 800-53 Rev. 5 lists it as implemented by the organization and the system and marks it as assurance-related, which signals that it is meant for systems where the consequence of a boundary failure justifies extra assurance. In Release 5.2.0 it carries one organization-defined parameter and no control enhancements, so the main decisions are the domains you define and the mechanisms you accept as enforcing them.
The risk it addresses is a compromise that spreads across domains that were meant to be kept apart, for example a cross-domain path reached from a lower-trust network or a shared platform where a software-only separation layer is the only thing standing between two sets of data. The hard part is rarely the control statement itself. Organizations struggle to define security domains precisely enough that an assessor can see where each one begins and ends, and to prove that the hardware mechanism, not only a software policy, enforces the separation. Before you commit, confirm with your authorizing official or governance body whether a tailored baseline or overlay in your program actually includes SC-49, and whether your platform and hardware can provide the enforcement you would need to document. For the software-enforced counterpart, see SC-50.
FedRAMP's Rev5 baselines do not require SC-49 at Class B, C or D, which is one reason it is rarely selected outside programs with a specific mandate. Read the FedRAMP reference for the baseline you are operating under and confirm there is no agency or contract requirement that adds it. If it is not required, the more practical question is whether your architecture has a domain boundary that software isolation cannot defend, and whether a hardware-backed design is justified by that risk. An implementation partner can help document domains, trace them to the evidence an assessor will examine, and test the boundary, but the decision to select SC-49 and the acceptance of residual risk stay with your organization, and only an independent assessor can report on whether the control is met.
Which systems and domains bring SC-49 into scope
SC-49 is not in any SP 800-53B baseline, so it enters a program only when the organization selects it through tailoring or an overlay. The cards below cover the decisions that determine whether it applies, how far it reaches, and who must produce the evidence an assessor will read alongside it.
Defined security domains and impact levels
Start with the list of security domains the organization has actually defined, and the impact level each one carries under its system categorization. SC-49 asks for hardware-enforced separation and policy enforcement between those domains, so a domain that exists only on a diagram gives an assessor nothing to test. Confirm which domains hold data at the highest impact levels, since those are the ones that justify a hardware boundary rather than a software one.
Systems that cross the hardware boundary
List every system that moves data or control signals between domains: cross-domain guards, shared hypervisor hosts, management networks and storage that serves more than one domain. Each crossing point is where the enforcement mechanism must hold, and each one needs a configuration record and audit trail. Confirm with the system owners whether any crossing is handled by a physical device, a host platform or a virtual function, because each produces different evidence.
Platform teams that own enforcement
Hardware separation usually spans several teams: infrastructure engineering for the hosts, network engineering for the boundary devices, and security operations for the logs. Assign one named owner for each enforcement point and document who changes firmware, policy and keys. Without that assignment, the assessor's interview with system owners tends to produce conflicting answers about who controls the boundary.
Hardware and hypervisor suppliers
Identify every third party that supplies processors, firmware, baseboard controllers, hypervisors or dedicated separation appliances. Their update and support terms determine whether the enforcement mechanism can be patched without breaking the separation claim. Ask each supplier for documentation of the isolation features it provides and the firmware versions in use, and record them in the system security plan so the evidence matches what is deployed.
Choosing SC-49 or SC-50
SC-49 is hardware-enforced, while SC-50 is software-enforced separation and policy enforcement between security domains, and both are outside the SP 800-53B baselines. SC-49 carries higher assurance but also higher cost in hardware, procurement and maintenance, and it constrains change. Where software separation with strong logging meets the risk acceptance of the authorizing official, selecting SC-50 is the lower-cost route. Document the rationale in the tailoring decision so the choice can be defended at assessment.
Related controls the assessor will read
Assessors read SC-49 alongside AC-4 (information flow enforcement), SA-8 (security and privacy engineering principles) and SC-50. AC-4 covers the flow rules that the hardware mechanism enforces, SA-8 shows that separation was designed in, and SC-50 defines the software alternative that must be justified if it is not selected. Map each related control to the same boundary diagram and evidence set so the assessor does not find contradictory descriptions of one domain.
How an assessor tests SC-49 and what they ask to see
This table maps the SP 800-53A assessment approach for SC-49 to the evidence an assessor requests and the findings they commonly raise. Read each row as a question the assessor will ask, then confirm the current procedure text in the OSCAL procedures before the audit, since the examine objects and wording are the basis for what gets tested.
| Assessment element | What the assessor checks | Evidence to prepare | Common finding |
|---|---|---|---|
| Determination statement | Whether the organization has defined the security domains and implemented hardware-enforced separation and policy enforcement between them, as set by the organization-defined parameter | Written list of security domains, the separation mechanisms chosen for each boundary and the approved parameter values | Domains are named informally or not defined, so the assessor cannot tell which boundaries the control covers |
| Examine: system design documentation | Whether the design shows where hardware separation sits between domains and how policy is enforced at each crossing | Architecture diagrams marking each domain boundary, the hardware component at each boundary and the policy enforcement points | Design relies on software isolation or logical segmentation and describes hardware separation only in general terms |
| Examine: system configuration settings and associated documentation | Whether the configured settings enforce the documented separation and policy, and whether the settings match the design | Configuration exports, firmware and hardware settings, policy rule sets and change records for each boundary component | Separation depends only on software configuration on a shared platform, so the hardware claim cannot be supported |
| Examine: system audit records | Whether enforcement actions and policy violations at domain boundaries are recorded and can be reviewed | Log samples showing allowed and denied cross-domain events, log source configuration and review records | Boundary events are not logged, or logs cannot be tied to a specific domain crossing |
| Interview | Whether administrators and engineers can explain the domains, the enforcement points and how a change to a boundary is approved | Named owners for each domain and boundary, documented change approval steps and staff who can walk through a sample crossing | Staff describe the intended separation but differ on which components enforce it |
| Test | Whether enforcement works in practice, including what happens when a crossing is not permitted | Recorded test cases for each boundary, expected and actual results and evidence that a denied crossing fails closed | No test shows that enforcement fails closed, so the assessor cannot confirm the policy holds under failure |
| Scope of tailoring | Whether SC-49 was selected by the organization, since no SP 800-53B baseline includes it | Documented selection rationale, the overlay or tailoring decision and the system categorization that led to it | Control is claimed without a recorded selection, or assessed without a clear justification |
How to implement SC-49 in six steps
This sequence turns the SC-49 requirement for hardware-enforced separation into a documented decision, a mapped set of hardware boundaries, tested enforcement behavior and retained evidence that an independent assessor can examine. Each step names the output it produces so the work can be checked before the assessment starts.
Define security domains and impact levels
The system owner, with security and architecture staff, lists every security domain the system contains or connects to, such as a management plane, a regulated data zone or an external integration zone. For each domain, record the data it holds, its impact level under the organization's categorization, and which domains must stay separated. The output is a domain register that names each domain, its owner, its impact level and its permitted flows. The step is complete when the register is approved and every boundary in the system design appears in it.
Select and document the parameter value
SC-49 has one organization-defined parameter in Release 5.2.0, so the organization must decide what it covers and record why. The control owner, with the authorizing official or risk owner, selects the value, explains the reasoning against the domain register and notes any domains where hardware enforcement is not chosen and the compensating measure instead. The output is a parameter decision record with a date, approver and link to the domain register. Ask the assessor early whether the proposed scope matches their reading of the parameter.
Map hardware boundaries and enforcement points
The architecture team draws each hardware boundary that separates the domains in the register, such as dedicated appliances, hardware security modules, separate physical hosts or isolated network hardware, and marks every enforcement point on it. For each point, note the vendor and model, the policy it enforces and the administrative path used to change that policy. Open-source platforms can run on dedicated hardware, but the mapping should show which hardware component makes the separation decision. The output is a boundary diagram with a matching table of enforcement points. The step is done when every flow allowed by the register crosses a mapped point.
Configure enforcement and test fail-closed behavior
The platform team writes the policy for each enforcement point, applies it through the change process and then tests it. Tests should include attempts that the policy must block, checks that permitted flows still work and failure tests that stop or disable the enforcement component to confirm the path fails closed rather than open. Packet filters such as OPNsense rules can record each match for review, which helps show that blocked attempts were seen. The output is a test plan, executed test results with pass or fail outcomes and a note on any remediation. Confirm with the assessor which test methods they will accept.
Enable and protect audit records
Each enforcement point must produce audit records that show policy decisions, configuration changes and enforcement failures. The operations team turns on the relevant logging, sends it to a central store, sets access so administrators cannot silently alter their own records and confirms that timestamps come from a synchronized time source. Test that a deliberate blocked attempt and a configuration change both appear in the store. The output is a log configuration record and a retained sample of logs for each enforcement point, with the retention period the organization has chosen recorded in the system documentation.
Record design and configuration in system documentation
The compliance lead updates the system security and privacy plan and the supporting design documents so they describe the domains, the parameter decision, the boundary diagram, the enforcement point configurations, the test results and the log sources. The configuration baselines for each enforcement point are stored under change control so later changes can be compared against them. The step closes when an engineer who did not build the system can trace SC-49 from the requirement to the diagram, the policy, a test and a log entry. That trace is the package an assessor will examine against the SP 800-53A procedure for this control, and the assessor, not the implementation partner, decides whether the evidence passes.
Evidence that passes an SC-49 assessment
SP 800-53A assesses SC-49 by examining a small set of objects: system design documentation, configuration settings and audit records. The cards below cover the artifacts that answer those examinations, and each one needs a named owner and a change trigger so it stays accurate between assessments.
Domain definitions and boundary diagrams
Start with the written list of security domains, the systems and data that belong to each, and the enforcement points between them. Diagrams should show every path that crosses a domain boundary, including management, backup and monitoring traffic that often gets overlooked. An assessor will compare the diagram against the live environment, so every domain change must update the diagram before the change is closed. Review the set at least once per cycle and after any merger, new hosting location or re-segmentation.
Organization-defined parameter decision
SC-49 carries one organization-defined parameter, so the organization must record what it chose and why. The decision record should name the domains it covers, the enforcement mechanism class selected and the risk basis for that choice, approved by the system owner and security leadership. Record who approved it, the date and the review trigger. Revisit the decision whenever the domain set or the assurance requirement for a domain changes.
Configuration exports and platform documentation
For each enforcement point, keep a dated export of its configuration and the vendor documentation for the hardware or platform it runs on, including firmware and hardware revision. Exports from firewalls, hypervisors, guards or hardware security modules should be generated by script and stored under version control so changes are traceable. Re-export and re-approve the configuration after every firmware update, hardware swap or rule change to a cross-domain policy. Confirm the exact capabilities of each platform with its vendor before relying on them as hardware enforcement.
Test records of blocked cross-domain flows
Test records show that prohibited flows between domains are actually blocked. Keep a test plan listing each prohibited flow, the method used (for example, attempted connection, forged packet or unauthorized file transfer), the expected result and the observed result with timestamps and tester identity. Retest after each boundary change. An assessor will look for failed tests that were tracked to closure, not only a clean first run, so record remediation against each finding.
Enforcement point audit records
Audit records from each enforcement point show denied and permitted cross-domain events over time. Confirm that logs capture the source, destination, protocol, decision and time, and that time sources match the rest of the environment. Forward logs to a store the enforcement point's administrators cannot alter, and sample them regularly to confirm denials are recorded. Retention periods should come from the organization's own audit policy, and the organization should confirm them with its assessor.
Where Coraza and OPNsense support SC-49 evidence and where they do not
Open-source tools can produce policy and log evidence for SC-49, but they cannot supply the hardware-enforced separation that the control names. SC-49 asks for separation that the platform and hardware enforce between defined security domains. A firewall rule or a web application firewall rule is software policy running on a host, so it sits outside the property the control describes. The practical use of these tools is to show how the boundaries you have defined are policed and recorded, which is the evidence the assessor will examine alongside the hardware controls.
Coraza (Apache-2.0) is a web application firewall compatible with ModSecurity SecLang rulesets and the OWASP Core Rule Set. It can inspect and log requests crossing an application boundary, with integrations for Caddy, HAProxy, Traefik and Nginx. Its rule files and audit logs can show which policy governed traffic between a public domain and an internal service. OPNsense (BSD-2-Clause) is a stateful packet filter whose rules pass, block or reject traffic by source, destination, port and protocol, and its aliases and per-rule match logging can show which network boundary rules were applied and exercised. Both are useful inputs to the audit record and system configuration evidence named in SP 800-53A for this control.
Before you rely on either tool for SC-49, confirm three things with your hardware vendor and within your own environment. First, confirm which hardware or hypervisor features provide the separation between domains, and obtain their configuration and documentation. Second, confirm that the Coraza and OPNsense rules, aliases and logging settings match the domain design you documented, and that logs are retained and protected. Third, confirm with your assessor which evidence they will accept for the separation itself. Engage an independent assessor for the conclusion, since a configured firewall alone does not establish hardware enforcement.
What meeting SC-49 costs in money and effort
This table lists the cost components of an SC-49 program, who is paid for each, whether it is one-time or recurring, and what moves it up or down. NIST does not estimate compliance costs, so no figures appear here; use the drivers to build a written scope and quote request.
| Cost component | One-time or recurring | What drives it up or down | Open-source effect |
|---|---|---|---|
| Hardware or platform for separated domains | One-time, with refresh cycles | Number of defined security domains, whether separation must be physical or hardware-backed, and whether existing hardware can be reused | Open-source software does not remove the cost of dedicated hardware, trusted platform modules or separate enclaves |
| Licenses for hypervisors or enforcement products | Recurring, usually annual or per host | Choice of commercial versus open-source hypervisor, number of hosts, and support tier required by the organization | Self-hosted open-source hypervisors and enforcement components remove license fees, but support contracts may still be needed |
| Engineering time to design and configure boundaries | One-time, with ongoing changes | Complexity of data flows between domains, number of cross-domain interfaces, and how much existing architecture must be reworked | Open-source components reduce software spend but the design and configuration hours stay with the organization or its partner |
| Testing of separation and policy enforcement | Recurring, tied to change and assessment cycles | Number of enforcement points, depth of penetration testing expected, and whether testing covers escape from each domain | Open-source test tooling lowers tool cost, but test design and results review still take staff time |
| Evidence upkeep (design documents, configuration records, audit records) | Recurring | How often configurations change, how well audit logging is centralized, and whether evidence is generated automatically | Self-hosted logging and configuration management can generate much of this evidence, but retention and review are organizational work |
| External testing or review | Recurring or per engagement | Scope of the domains tested, whether an independent assessor reviews the design, and the number of assessment rounds | Open-source tooling does not replace independent assessment, which must be paid for separately |
| Auditor or assessor sampling | Recurring, per assessment | Number of domains and enforcement points sampled, and whether the organization's evidence is complete and well organized | Clean, reproducible evidence from self-hosted systems can reduce sampling effort, but the assessor sets the sample |
Who owns SC-49 and what an implementation partner can take on
Your organization owns the SC-49 decision. Before any hardware is specified, your leadership must decide whether the system needs hardware-enforced separation between defined security domains at all. That decision belongs to the authorizing official or the equivalent accountable executive, because SP 800-53B does not assign SC-49 to any baseline and it only applies when you select it through tailoring or an overlay. Your team also defines the organization-defined parameter, names the domains, and accepts any residual risk in writing.
- Selection and tailoring: record why SC-49 is in or out of the system's control set, citing the tailoring decision and the related controls AC-4, SA-8 and SC-50.
- Domain definition: name each security domain, its data classification and the boundary between domains.
- Risk acceptance: document who accepts any gap between the chosen hardware controls and the stated domain requirements.
- Ownership of outcomes: assign a named owner for the control, its configuration records and its periodic review.
- Budget and contract terms: fund the work and write the partner's deliverables into a fixed scope before work starts.
Before signing, confirm that your internal owner can explain each domain boundary without the partner in the room.
An implementation partner prepares the systems and evidence that show how SC-49 is met. DeployOpen, for example, plans, configures and documents self-hosted open-source platforms inside your own cloud accounts, data centers or air-gapped networks. The partner does not decide whether SC-49 applies, does not accept risk and does not sign statements that the control is satisfied. Its output is the material an assessor will examine: domain designs, configuration, test records and evidence packs.
- Domain designs: draft the separation architecture, showing how each domain is isolated and where policy is enforced.
- Configuration: set up the enforcement points and record the settings that an assessor will examine.
- Test records: run and document tests that show policy is enforced across domains, including negative tests.
- Evidence packs: collect system design documentation, configuration baselines and audit records mapped to the SP 800-53A examine objects.
- Handover: train your staff to operate and review the controls after the engagement ends.
For any proposed partner, ask for a written scope listing each deliverable, and confirm what the partner will not do, including any statement about control status.
Only an independent assessor, auditor or certification body issues findings, reports or certificates. The assessor tests the control against the determination statement in SP 800-53A and decides whether the evidence supports it. Independence means the assessor must not design, configure or operate the controls it tests, because that would mean reviewing its own work. This is the line between an implementation partner and an assessor, and it applies even when the same company offers both services.
- Assessment procedure: the assessor examines design documentation, configuration settings and audit records, interviews staff and tests the enforcement behavior.
- Findings: the assessor reports whether the determination statement is satisfied, partially satisfied or not satisfied.
- Independence: the assessor should not have prepared the evidence it is evaluating, so ask how the firm separates advisory and assessment work.
- Authority: only the assessor's report or certificate counts as independent assurance, and DeployOpen does not issue audit reports or certifications.
- Scope agreement: confirm with the assessor, before work starts, which assessment method and objects will be used.
Before engaging an assessor, confirm its qualifications for your framework and whether it has a conflict with the partner that built your evidence.
Where SC-49 implementations usually fall short
SC-49 is not in any SP 800-53B baseline, so organizations that adopt it usually do so for a specific high-assurance domain boundary. The gaps below tend to appear where that boundary is drawn, configured, tested and documented, and each one can be closed with an artifact or test an assessor can examine.
Domains drawn but not configured
Architecture diagrams often show security domains as clean boxes, while the running system shares hosts, hypervisors, storage or management paths across them. Before assessment, export the actual domain membership from configuration (network segments, VLANs, enclave assignments, hypervisor pools) and reconcile it against the diagram. Any mismatch is a finding waiting to happen. Keep the reconciled export with the system design documentation, since assessors examine that documentation directly.
Software settings described as hardware
A separation mechanism that depends on a software policy, a hypervisor setting or an access control list is not hardware-enforced, even when vendors market it that way. Document, for each boundary, which component enforces it and where that enforcement lives. Ask the vendor in writing whether the mechanism relies on a dedicated hardware element such as a separate device, and record the answer. Describe software-only enforcement honestly in the plan, because an assessor will test what the mechanism actually depends on.
No documented parameter decision
SC-49 carries one organization-defined parameter in Release 5.2.0, and the assessment procedure expects the organization to have set it. Many programs leave the parameter blank or copy a value from another system without a rationale. Record the chosen definition of the security domains and the enforcement points in the system security plan, with the decision owner and date. Tie each parameter value to the domain inventory so the decision can be traced during the assessment.
Fail-closed behavior never tested
Policy enforcement between domains must fail closed, meaning traffic or data is blocked when the enforcement point is unavailable, misconfigured or overloaded. Teams often verify that allowed flows work and never verify what happens when the enforcement function stops. Write test cases that disable the enforcement component, corrupt a policy rule and exceed capacity, then record whether cross-domain traffic is blocked. Retain the test results and the remediation for any case that failed open.
Audit records not retained or reviewed
Assessors use system audit records as examine objects for SC-49, so the logs must show denied cross-domain attempts, policy changes and enforcement failures. Confirm that the firewall, hypervisor or guard logs these events, that they are forwarded to a central store outside the domains they describe, and that retention matches the organization's audit policy. Open-source firewalls such as OPNsense can log each rule match for review, but the review cadence and the person accountable for it must be written down.
Boundary changes skip documentation
A new VLAN, a shared storage path or an added management interface can silently move a component across a domain line. When this happens, the domain inventory, the enforcement rules and the system design documentation fall out of step. Require that every change to a domain boundary triggers an update to the design documentation and a repeat of the cross-domain tests before the change is closed. Keep the change record linked to the boundary inventory so the assessor can follow a change from request to verified state.
Questions buyers ask about SC-49 cost, effort and outside help
Is SC-49 required in a NIST SP 800-53 baseline?
No. SP 800-53B does not assign SC-49 to the low, moderate, high or privacy baseline, so it applies only when your organization selects it through tailoring or an overlay. Appendix C of SP 800-53 Rev. 5 lists it as implemented by the organization and the system and marks it as assurance-related. The FedRAMP Rev5 baselines do not require it at Class B, C or D. Selection is therefore a risk decision: if your system handles domains that need hardware-enforced separation, document why the control is in scope. If it is not in scope, record that rationale in your tailoring decisions so an assessor can see it was considered.
How much does SC-49 cost to implement and assess?
NIST does not estimate certification or compliance costs, so no public figure applies to your environment. The main drivers are the number of security domains you define, the hardware you must add or replace, the number of systems that must reference the separation mechanism, and how much design documentation and configuration evidence already exists. Costs fall into one-time work (design, hardware, configuration, documentation) and recurring work (monitoring, review, re-assessment after changes). Ask any provider for a quote that separates hardware, labor, testing and assessment support, and that states which items are one-time and which recur.
How long does it take to implement SC-49?
NIST does not set implementation timelines for SP 800-53 controls; those are left to the authorizing program or agency. Duration depends on scope: how many domains need separation, whether hardware procurement is required, how mature your change control is, and how many accreditation or assessment cycles run in parallel. Under a fixed-scope engagement, DeployOpen agrees deliverables and timelines in writing before work starts, so the schedule follows from the agreed scope. Ask for a written plan that lists each domain, the dependencies and the evidence due at each milestone.
What does my team need to provide for SC-49 work?
You own the control, so your team must supply the inputs that prove it works. Expect to provide the system architecture, a list of security domains and their trust boundaries, current configuration baselines, access and change records, and the system audit records an assessor will examine. Named owners must be able to answer interview questions and approve design decisions. Plan time for hardware access, maintenance windows and a sign-off process. The more complete these inputs are at the start, the less rework the assessment will generate.
Can our internal team implement SC-49 without outside help?
Yes, if your team has staff who can design hardware-enforced separation, configure it, and document it in a form an independent assessor can test. Many organizations find the hard parts are the design review, consistent evidence collection and keeping documentation current after changes. Confirm internally whether you have engineers with hardware security experience, time to run a pilot, and a plan for ongoing monitoring. If any of these are missing, an implementation partner can fill those gaps, but your organization still owns the control and its decisions.
How does SC-49 differ from SC-50 in practice?
SC-49 requires hardware-enforced separation and policy enforcement between defined security domains, while SC-50 covers software-enforced separation for domains that need more than baseline isolation. The Release 5.2.0 catalog lists AC-4, SA-8 and SC-50 as related controls for SC-49. In practice, choosing SC-49 means you have decided that software isolation alone is not sufficient for a domain. Many designs combine both, so confirm with your assessor which control mechanisms cover which domain boundaries, and document that mapping in your system security plan.
What does an implementation partner provide, and what does it not?
An implementation partner such as DeployOpen plans, implements, configures, hardens, documents and supports self-hosted open-source platforms in your own infrastructure, and prepares systems, controls and evidence for assessment. It does not own your controls, does not make your risk decisions, and does not issue audit reports, attestations or certifications. Only an independent auditor, assessor or certification body can do that. Before engaging, ask for a written scope that names the domains covered, the deliverables, the evidence produced and the parties responsible for each item.
How DeployOpen scopes and prepares SC-49 evidence
DeployOpen approaches SC-49 Hardware-enforced separation and policy enforcement as a scoped engagement inside your own infrastructure. We prepare the systems, configuration records and evidence an assessor would examine, while your organization owns the control decision and an independent assessor issues any conclusion about it.
How we scope
- Confirm with your team whether SC-49 is selected in your tailoring or overlay, since no SP 800-53B baseline includes it.
- Define the security domains, the hardware separation mechanisms in scope and the systems that enforce policy between them.
- Record the organization-defined parameter for SC-49 and the boundaries it covers in the written scope before work begins.
How we build
- Document the system design and configuration settings that show how hardware separation and policy enforcement are implemented.
- Configure and verify the enforcement points between domains, and test that policy blocks traffic or access outside approved paths.
- Set up audit records for enforcement decisions so examined logs show the separation operating as documented.
How we hand over
- Deliver the design documentation, configuration baselines and test results mapped to the SC-49 determination statement.
- Provide an evidence index listing where each examine object lives, such as design documents, settings and audit records.
- Walk your assessors and engineers through the handover package and record open items as agreed in the written scope.
How we support
- Ongoing support, upgrades and continuous testing are available as a retainer after handover.
- Re-verify enforcement settings and update documentation when domains, hardware or policy rules change.
- Ask any implementation partner to confirm in writing which parts of SC-49 remain your responsibility and which are assessed by an independent auditor.